1.Door Assemblies are designed to resist exterior blast pressures, minimum, SDI
A250.8, physical performance Level A, Model 2, with welded edges.
2.Door
Assemblies have successfully passed 1.0 “PSI” of Static Pressure Loading in
accordance with ASTM E-330. This pressure was surpassed in both seating and
unseating configurations, these seating pressures, have also passed the
“Out-swing” requirements of, UFC 4-010-01. Large Missile Impact level “D” was
met as well.
3.We are certified under positive pressure testing UL 10 C and ISO
3008, as well as, IBC 2003, NFPA 80, HMMA 861 and we meet or exceed SDI 100
manufacturing requirements such as Cycle and Twist protocols.
4.The following
table shows the constructions specifications and the criteria disciplines’ for
our Hollow Metal Doors and Frames tested for Hurricane Wind Loads which carry
the “Approved Status” on the Florida Building Commissions” web site,
http://www.floridabuilding.org. Door Assemblies described are posted in
FL-9067.1.
Accepted Engineering Practice 2007, ASTM E1300- 2002, ASTM E1886-
2002, ASTM E1996- 2002, ASTM E330- 2002, TAS 201, 202, & 203-1994, ASTM A250
2002 Verified By: Wendell W. Haney, P.E. 54158 |